Water Analysis Instruments

Online Total Nitrogen Auto-Monitor

Model: :PT6000

The ULT200 ultrasonic level transmitter provides reliable non-contact level measurement for liquids, solids and slurries. With advanced echo processing technology, it delivers high accuracy even in challenging industrial environments.

  • 24-Hour Response Fast turnaround time
Get a Quote

Model

PT6000

Stek 300

Detection Principle

Potassium Dichromate

Oxidation

Spectrophotometry

Nessler's Reagent

Spectrophotometry

Salicylic Acid

Spectrophotometry

Potassium Persulfate

Oxidation-Ammonium

Molybdate

Spectrophotometry

Alkaline Potassium Persulfate

UV Digestion UV

Spectrophotometry

—

Measuring Range

0-20000mg/L

0-10,20,50mg/L

Range Segmentation (Graded

Ranges) :0-2,5 ,10,30,

100,500,1000mg/L

0-1/5/10/30/150 mg/L;

0-1 ,2 ,10,20 ,50,100,

200mg/L

0-2.5/20/50/100/200

mg/L

—

Indication Error

Upper Range

Limit:20%*

±5%

20%*

±3%

±3%

TP<0.10 mg/L时, ±0.003mg/L

TN≤0.5mg/L

±0.025mg/L

Sampling Volume Error: ±5%

Proportional Sampling

Volume Error: ±7%

System Clock Time Control

Error: ≤0.1% (A1) and Δt ≤

30 seconds (A12)

Refrigerator Temperature

Control Error: ±2°C

Upper Range

Limit:50%*

±1%

50%*

±3%

Upper Range

Limit:80%*

±1%

80%*

±3%

TP≥0.10 mg/L时,±3%

TN>0.5mg/L

±5%

0-1000Upper

Range

±10%

Lower Limit of

Quantification

(LLOQ)

≤5mg/L(±30% of reading)

≤0.05mg/L(±30% of reading)

≤0.005 mg/L

≤0.005 mg/L

≤0.1 mg/L

—

Repeatability

≤3%

≤2%

≤1%

±1%

±3%

—

24h Zero Drift

±5 mg/L

≤0.005mg/L

≤0.01 mg/L

Zero Drift:±0.5%

Zero Drift:±3%

—

24h Span Drift

≤2%

≤0.5%

≤1%

Span Drift:±1%

Span Drift:±3%

—

Chloride

Interference

±3%

—

≥720h/cycle

—

Real Sample

Comparison

Accuracy for COD < 50 mg/L: ≤ ±3 mg/L

NH3N<2 mg/L

≤0.1mg/L

NH3N<2 mg/L

≤0.1mg/L

TP<0.1 mg/L时,≤ ±0.01mg/L

TN<2mg/L

±0.2 mg/L

—

COD ≥ 50 mg/L: ≤ ±5% of

reading

NH3N≥2mg/L

≤5%

NH3N≥2mg/L

≤5%

TP≥0.1 mg/L时,≤±10%

Tn≥2mg/L

±10%

—

Minimum

Maintenance

Interval

≥720h/cycle

Vertical Sampling Height: ≥

8m

Measurement

Time

≤40 min

≤30 min

≤40 min

≤45min

Horizontal Sampling

Distance:250m

Dimensions

(H×W×D)

3 6 0 m m * 2 5 0 m m * 5 0 0 m m ( W * D * H ) + including Pre-treatment Unit

480*485*1394mm

(W × D × H)

Weight

Net Weight<18Kg;Shipping Weight<20Kg

70kg

Environmental

Conditions

Temperature:5 - 40℃:Humidity: ≤90%

Temperature:5~40℃

Humidity:(65±20)%

Power Supply

90V-250V,50HZ±10%

220VAC±10%/50-60Hz

Data Interface

Digital Communication: MODBUS protocol via RS232/RS485, RJ45 (dedicated interface for water quality cloud) Analog Output: 4 - 20 mA

Multi-functional Data

Transmission Interface: 4-

20mA, RS232, RS485,

supports I/O input and

output, and has a reserved

flow meter communication

interface.

Key Features

Low quantification limit (5

mg/L), significantly exceeding national COD analyzer

standards, suitable for diverse applications.

5-year reliability design with optimized reagent formula minimizes sulfuric acid

corrosion on valves, ensuring long-term stability.

Low operational cost:

Separate disposal for waste

liquid and water; waste

generation as low as 6 mL per test.

Patented design solves

measurement inaccuracies in high-salinity water samples. Patented micro-volume

dosing technology (5 μL) guarantees measurement accuracy.

Fully compliant with latest national standards for

pollution source monitoring. Separate waste liquid/water disposal minimizes waste

volume.

Compact design for easy

transportation and installation. Customizable solutions based on water conditions to reduce user operational costs.

Routine maintenance

completed within 5 minutes. Remote diagnostics and

maintenance; fault reporting via WeChat QR code scan for precise after-sales service.

Compliant with dynamic

control technical requirements.

Built-in turbidity and color

compensation; resists turbidity interference up to 800 NTU for improved accuracy.

Separate waste liquid/water

disposal reduces waste volume and operational costs.

Low detection limit with auto- dilution and intelligent multi - range switching for diverse

applications.

Automatic zero andspan verification ensures data accuracy and validity.

Proprietary algorithm and

optical design resists turbidity interference up to 800 NTU. High reliability with premium pumps, valves, detectors, and chips.

Patented dosing technology ensures precise measurement for complex water matrices. "One-Touch Operation" for simplified use.

Optimized reagent formula

extends shelf life to 3 months, solving reagent degradation issues.

Innovative UV-catalyzed oxidation technology

eliminates digestion tube breakage caused by high temperatures, enhancing instrument reliability.

Dual-optical-path

measurement system removes interference from organic

matter in samples.

High-quality imported light source ensures accurate and reliable measurements.

Deep-cleaning of critical

valves prevents clogging and reduces operating costs.

Sampling Modes:

Quantitative, time-based

quantitative, time/flow

proportional, and fixed-flow quantitative sampling.

Sample Retention: Supports retention for (exceedance), synchronized, direct, serial

port controlled, and manual sampling.

Sample Distribution:

Provides real-time or

composite samples to

multiple online analyzers simultaneously.

Data Logging: Retains

records for samples, door access, power outages, and alarms.

Self-Diagnostics: Features system fault auto-alarm and status information

display/output.

Precise Temperature

Control: Digital refrigeration ensures accurate and uniform temperature in the storage

chamber.

Typical

Applications

Monitors Chemical Oxygen

Demand in pollution sources,

surface water, and other

water bodies.

Monitors Ammonia Nitrogen

in pollution sources (industrial

& domestic wastewater).

Primarily monitorsAmmonia

Nitrogen insurface

water,groundwater, pollution

sources, anddrinkingwater.

MonitorsTotalPhosphorusin

pollutionsources,surface

water,groundwater,drinkingw

ater, and other waterbodies.

Primarily monitors Total

Nitrogen in surface water,

groundwater, drinking water,

and other water bodies

(online).

For surface water monitoring

(rivers, lakes, reservoirs) and

enterprise pollution source

discharge outlets.

Certifications

Software Copyright Registration

Message
Contact number

+86 18961557757

+86 18018362100

Back to top