Water Analysis Instruments

Online Total Lead (Pb) Water Quality Auto - Monitor

Model: :ADG687

The ULT200 ultrasonic level transmitter provides reliable non-contact level measurement for liquids, solids and slurries. With advanced echo processing technology, it delivers high accuracy even in challenging industrial environments.

  • 24-Hour Response Fast turnaround time
Get a Quote

Model

ADG672

ADG673

ADG688

ADG687

ADG668

Detection Principle

Zincon Spectrophotometry

Phenanthroline

Spectrophotometry

3,5-Br₂-PADAP

Spectrophotometry

Porphyrin Spectrophotometry

Diphenylcarbazide

Spectrophotometry

Measuring Range

0-2, 10,20, 50mg/L

(Extendable)

0-5,25, 100mg/L

(Extendable)

0-1, 2 ,10mg/L(Extendable)

0-0.2 ,0.5 , 1 ,2mg/L

(Extendable)

0-1, 5 ,25mg/L

Indication Error

±5%

±3%

Precision

≤5%

≤3%

≤1%

Lower Limit of

Quantification

(LLOQ)

≤0.03 mg/L

≤0.05 mg/L

≤0.05mg/L

Zero Drift

±5%

±1%

≤1%

Span Drift

±5%

≤3%

Voltage Stability

±5%

±1%

±3%

±1%

AmbientTemperature Stability

±10%

±3%

±5%

±10%

Ionic Interference

±20%

±15%

±5%

±15%

±3%

Carry-over

±0.1 mg/L(verified with 20%

and 80% of standard solution

concentration)

±5%

±0.004mg/L

±5%



Real Sample

Comparison


<0.2 mg/L 时 ,≤0. 1 mg/L

For sample concentrations ≤

0.50 mg/L,the comparative

measurement error shall be

≤ 0.05 mg/L.

For sample concentrations ≤

0.50 mg/L,the comparative

measurement error shall be

≤ 0.015 mg/L.

TPb ≤0.050 mg/L , ±0.005

mg/L


Cr6 +<0.4 mg/L, ±0.04 mg/L



≥0.2 mg/L 时 ,≤10%

For sample concentrations ≥

0.50 mg/L,the comparative

measurement error shall be

≤ 10%.

For sample concentrations ≥

0.50 mg/L,the comparative

measurement error shall be

≤ 15%.


TPb>0.05 mg/L ,≤10%


Cr6 +≥0.4 mg/L, ±10%

Measurement Time

≤50 min

≤60 min

≤40 min

≤45 min

Minimum

Maintenance Interval

≥720hours/cycle

Data Availability Rate

≥90%

≥95%

≥90%

≥95%

Consistency

Deviation

≤10%

≤1%

≤3 %

≤1%

Main Unit

Dimensions

3 6 0 m m * 2 5 0 m m * 5 0 0 m m ( W * D * H ) +(Including Pre-treatment)

Instrument Weight

Net Weight<18Kg;Shipping Weight<20Kg

Environmental

Requirements

Temperature:5 - 40℃:Humidity:≤90%

Power Supply

AC(220±22)V ,(50±1) Hz

Digital

Communication

Serial: 1 × RS232, 1 × RS485 (supports MODBUS protocol) Network: 1 × RJ45 Ethernet

Output

Analog Output: 1 × Isolated 4-20 mA Digital Outputs: 1 ×Switch/Dry Contact, 1 × DC 24V Sourcing Output





Product Features

Complies with US EPA Method 7063, 7472, DIN 38406, ISO 6636-1,and ISO 8391-1 standards.

Patented detection cell technology significantly improves sensitivity and enables simultaneous multi-metal detection in a single instrument.

Patented sampling and advanced fluidic technology eliminate cross-contamination and prevent tubing clogs.

Innovative modular design allows for simultaneous analysis of multiple parameters, with flexible parameter combinations per user requirements.

Measurement results are unaffected by sample color or turbidity.

Automatic calibration ensures consistent and reliable test results.

Low reagent consumption reduces operating costs.

Certified by China National Environmental Monitoring Centre for instrument suitability, ensuring accurate and valid

monitoring data.

Low reagent and waste generation, reducing operational costs.

Optimized reagent formulation masks interfering factors in water for more accurate results.

Supports remote diagnostics and maintenance; fault

reporting via WeChat QR code scan for precise and rapid after-sales service.

Compliant with dynamic control technical requirements.

Compact design for easy transportation and installation.


Typical Applications


Surface water, groundwater, drinking water

Metal processing, metal

smelting, battery industry,

petrochemical industry

Wastewater discharge from

metal processing,

electroplating, tanning and

other industries

Product Certification

Software Copyright Registration

Message
Contact number

+86 18961557757

+86 18018362100

Back to top