Water Analysis Instruments

Online Nitrate Nitrogen Water Quality Auto - Analyzer

Model: :ADG676

The ULT200 ultrasonic level transmitter provides reliable non-contact level measurement for liquids, solids and slurries. With advanced echo processing technology, it delivers high accuracy even in challenging industrial environments.

  • 24-Hour Response Fast turnaround time
Get a Quote

Model

ADG678

ADG679

ADG675

ADG676

ADG677

Test Method

Spectrophotometry

Phosphomolybdenum Blue Spectrophotometry

Potassium Persulfate

Spectrophotometry

Ethylenediamine

Spectrophotometry

Measuring

Range

0-1.5mg/L

(Segmented measurement,

extendable)

0-10mg/L

(Segmented, auto-ranging)

0-50mg/L

(Segmented measurement,

extendable)

0-100mg/L

(Segmented measurement,

extendable)

0-2mg/L

(Segmented measurement,

extendable)

Detection Limit

≤0.03mg/L

0.05mg/L

—

Resolution

0.001

—



Accuracy



±10%

Standard solution and water

sample concentration ≤0.5

mg/L, not exceeding ±0.05

mg/L

Standard solution and water sample concentration ≥0.5 mg/L, not exceeding ±10%

Standard solution and water

sample concentration ≤2

mg/L, not exceeding ±0.2

mg/L

Standard solution and water sample concentration ≥2.0 mg/L, not exceeding ±10%



±10%

Repeatability

±5%

±10%

Zero Drift

—

±5%

Span Drift

±5%

±10%

Measurement

Cycle

< 40 min

< 20 min

< 50 min (Digestion time configurable)

Sampling

Interval

Interval (adjustable), On-the-hour, or Triggered mode; configurable.

Calibration

Interval

Automatic (interval: 1-99 days, adjustable) or Manual (based on actual sample); configurable.

Maintenance

Interval

Maintenance Interval:   > 1 month (approx. 30 min per session).

HMI (Human -

Machine

Interface)

Touchscreen for display and command input.

Self-diagnostics

& Protection

Self-diagnosis of operational status. Data retained during exception or power loss. Auto-purge of residual reactants and auto-recovery after reset or power

restoration.

Data Storage

Data Storage:   5years.

Input Interface

Digital (switch) inputs/outputs.

Output Interface

1x RS232 output, 1x RS485 output,2x Isolated 4-20mA analog outputs

Operating

Conditions

Indoor. Recommended: 5-28°C, Humidity ≤90% RH (non-condensing).

Power Supply &

Consumption

AC220±10%V,50±0.5Hz,≤150W,exclusive of sampling pump

Dimensions

Dimensions (H x W x D):   1470 x 500 x 400 mm.






Working Principle




Under acidic conditions (pH

1.5~2.0), aniline compounds

undergo diazotization with nitrite.

The resulting diazonium salt then

couples with N-(1 -

naphthyl)ethylenediamine

dihydrochloride to form a magenta

dye, which is quantified by

spectrophotometry.





Urea reacts with diacetyl monoxime

and antipyrine to form a yellow

complex. The absorbance is

proportional to the urea

concentration.


The sample is mixed with a catalyst

and a strong oxidizing digesting

agent. Under high-temperature,

high-pressure acidic conditions,

polyphosphates and other

phosphorus compounds in the

sample are digested and oxidized

by the strong oxidant to produce

phosphate ions. In thepresence of

the catalyst, the phosphate ions

form a colored complex in a

strongly acidic molybdate solution.

The analyzer detects the change in

this color and converts it into an

orthophosphate concentration

output. The amount of colored

complex formed is equivalent to

the orthophosphate concentration.



After mixing with a masking agent,

nitrate nitrogen (present as free

ammonia or ammonium ions)

reacts with a potassium persulfate

chromogenic reagent in an alkaline

environment and in the presence of

a sensitizer to form a colored

complex. The analyzer detects the

change in this color and converts it

into a nitrate nitrogen

concentration output. The amount

of colored complex formed is

equivalent to the nitrate nitrogen

concentration.




In a phosphoric acid medium at pH

1.8±0.3, nitrite reacts with

sulfanilamide to form a diazonium

salt, which then couples with N-(1 -

naphthyl)ethylenediamine

dihydrochloride to produce a red

dye. The maximum absorption of

this dye occurs at a wavelength of

540 nm.

Certifications

Software Copyright Registration

Message
Contact number

+86 18961557757

+86 18018362100