Water Analysis Instruments

Online Manganese (Mn) Water Quality Auto-Monitor

Model: :ADG671

The ULT200 ultrasonic level transmitter provides reliable non-contact level measurement for liquids, solids and slurries. With advanced echo processing technology, it delivers high accuracy even in challenging industrial environments.

  • 24-Hour Response Fast turnaround time
Get a Quote

Model

ADG667

ADG669

ADG670

ADG671

Detection Principle

Dimethylglyoxime

Spectrophotometry

Diphenylcarbazide

Spectrophotometry

Bathocuproine Spectrophotometry

Formaldoxime Spectrophotometry

Measuring Range

0-2/10/20mg/L(Extendable)

0-1/5/25mg/L(Extendable)

0-1/5 /150mg/L(Extendable)

0-5/20/100 mg/L(Extendable)

Indication Error

±5%

±3%

±5%

Detection Limit (DL)

—

≤0.005 mg/L

—

Precision

—

≤3%

≤5%

Lower Limit of

Quantification (LLOQ)

≤0.02mg/L ±30% of reading

—

≤0.01 mg/L

≤0.05 mg/L

Repeatability

≤5%

—

Zero Drift

±5%

±1%

≤5%

±5%

Span Drift

±5%

±3%

≤5%

±5%

Voltage Stability

±5%

±1%

Ambient Temperature Stability

±5%

±10%

±5%

±3%

Ionic Interference

±15%

±10 %

±15%

Carry-over

±10%

±5%

Standard Addition

Test

≤0.50 mg/L,80-120%

—


>0.50 mg/L,90%-110%

—


Real Sample

Comparison

≤0.20 mg/L,  ≤±0.04mg

TCr<0. 1 mg/L , ±0.01 mg/L

TCu ≤ 0.50 mg/L, ≤0. 1mg/L

≤ 0.05 mg/L for sample  concentrations ≤ 0.50 mg/L


>0.20 mg/L,  ≤15%

TCr ≥ 0. 1mg/L , ±10%

TCu > 0.50 mg/L, ≤15%

≤ 10% of reference value for sample concentrations ≥ 0.50 mg/L

Measurement Time

≤55 min

≤40 min

≤60 min

Minimum

Maintenance Interval

≥720 h/cycle

Data Availability Rate

≥95%

≥90%

≥95%

Consistency Deviation

≤5%

≤10%

≤ 5%

≤1%

Main Unit Dimensions

(H × W × D)

3 6 0 m m * 2 5 0 m m * 5 0 0 m m ( W * D * H ) + (Including Pre-treatment Unit)

Instrument Weight

Net Weight<18Kg;Shipping Weight<20Kg

Environmental

Requirements

Temperature:5 - 40℃:Humidity:≤90%

Power Supply

AC(220±22)V ,(50±1) Hz

Digital

Communication

Serial:   1 × RS232, 1 × RS485 (MODBUS protocol supported) Network:   1 × RJ45 Ethernet

Outputs

Analog Output:   1 × Isolated 4-20 mADigital Outputs:   1 ×Switch/Dry Contact, 1 × DC 24V Sourcing Output



Key Features

Complies with US EPA Method 7063, 7472, DIN 38406, ISO 6636-1,and ISO 8391-1 standards.

Patented detection unit significantly improves sensitivity and enables simultaneous detection of multiple heavy metals in a single instrument. Patented sampling technology and advanced fluidic system eliminate cross-contamination and prevent tubing clogs.

Innovative modular design allows for simultaneous analysis of multiple parameters, with flexible parameter combinations to meet user needs. Measurement results are unaffected by sample color or turbidity.

Automatic calibration ensures consistent and reliable test results.

Low reagent consumption reduces operational costs.

Typical Applications

Surface Water, Groundwater, Drinking Water

Product Certifications

Software Copyright Registration

Message
Contact number

+86 18961557757

+86 18018362100

Back to top